The only difference for us was that the capacitor had no distinguishable bulging or bloating at all. If there is 24v at coil of contactor and 240volt at line with contator closed...then [if neither compressor or condensor fan are running]: 1. If it starts and runs, then I would replace the fan motor and capacitor.If the motor does not start in the last step, then I would check for 220 volts coming tester shows 16 volts across the white (used for cool and plugged into the Y port) there's no heat connection. http://zenlinux.org/fan-not/psu-fan-not-spinning-on-startup.html

Spins freely until power hits it. When the capacitor is called to action, it is supposed to release its energy and give the fan a sort of electrical kick in the pants. Perfect timing, right? This was exactly what was wrong and was an easy fix.

Ac Unit Fan Not Spinning

You can take the capacitor to the nearest U-FIX-IT store for free testing and a new capacitor may buy you a little more time.JimReply Jennifer says: September 23, 2016 at 7:56 What and Where is the A/C or Heat Pump Compressor/Condenser Unit Fan? Of course they said that it would apply to any repairs I had done. *rolls eyes* Anyway I was in my house yesterday with a broken down a/c, 98 degrees in When the unit is not running, I would use the wiring diagrams on the furnace and the outdoor unit to chase the missing voltage (either 220 volts or 24 volts) back

It was unclear if it was the outdoor unit or the indoor unit. They should definitely be looking for something more on the 2nd trip for the same issue. I replace the contactor and it kicked right off and ran great for about 3 days. Ac Fan Not Working In Car I'm stuck in a trash can, help?

Again fan wouldn't start, except by using the stick method. Do you see ice on the lines connecting the indoor and outdoor units or is there water around the furnace? The original capacitor was a GE brand part #97F9856 with ratings of 40uf 5uf, 440vac,+6% -6%, 50/60Hz. http://www.doityourself.com/forum/air-conditioning-cooling-systems/228058-central-c-no-cold-air-blowing-outside-fan-not-running.html If your motor requires a 5 mf capacitor, then the symptoms are pointing toward a bad motor.JimReply Jaece says: July 25, 2016 at 2:52 pmThank you for quick response.Reply M says:

I would cut off the power to the outdoor unit until the fan motor is running again if it was mine. Ac Unit Not Turning On The fan spins freely and I have 220 at the unit. Over time, these fans just wear out and die. It is a 24 year old unit so the warranty company on the house covered that.

Ac Inside Fan Not Working

Keeping your air conditioner's coils clean and your air filter changed when needed can keep the running temperature of your unit down, thus helping to keep your own temperature down when http://georgebrazilhvac.com/blog/why-is-my-outdoor-a-c-units-fan-not-spinning Low voltage could cause things to burn up just as bad as higher. Ac Unit Fan Not Spinning After about 5 minutes the compressor kicked on too. Ac Compressor Not Running What do I do from here?Thanks,AndyReply Jim Plummer says: July 25, 2016 at 2:20 pmAndy,The next step is to verify 24 volts being sent from the terminal board on the indoor

Fan is brand new. Check This Out It's 90 in my housing and creeping up slowly, can anybody suggest anything at all? Checking the contactor, I did have 240 at the contactor and 24v through the coil. Could this be it or am I completely off base?(I work in electronics repairs, so I like to try to figure out things that are going wrong. Why Is My Ac Outside Unit Not Turning On

Or did the professional give me the wrong capacitor? The main indicator you mentioned: "Loud hum, but the fan is not spinning). The units fan does not stop running. Source It is even cheaper than that of the outdoor unit so is worth giving a shot.

Replaced it within less than 3 minutes and the AC is back up and running. Ac Fan Capacitor In extreme situations the coil must be removed by a technician and powerwashed. If you do not have power to the unit, you should check the wiring between the electric panel and the unit.

You'd be quite clumsy to short the 24v while changing out a capacitor BUT, yes, you can take the extra precaution and shut down the furnace power if you're more comfortable

FacebookTwitterGoogle+YoutubeHyde’s Family Comfort PlanSpecial OffersFinancingGet Your Free Estimate Call Us Today(760) 360-2202ServicesInstallationRepairsService PlanDuct SealingInsulationZoningCommercial HVACEnergy ConservationIndoor Air QualityAir Cleaners and Air PurifiersDuct SealingUltraviolet Light Air PurificationAir ExchangersService AreaProductsAir ConditioningMini SplitsPackage UnitsIndoor A motor goes bad so they replace the motor....goes again and they do it again....and again....and then blame the motor company. Could this have caused the fan to stop spinning? Outside Ac Unit Won't Turn On The family is coming over this weekend and you're very busy making all the necessary arrangements, when suddenly the A/C quits working.

Yes No Sorry, something has gone wrong. We purchased the house new. Took side cover off and noticed capacitor was bulging like all pictures I've been seeing of what the bad ones look like. http://zenlinux.org/fan-not/corsair-rm750-fan-not-spinning.html Turned everything on and fan works but compressor just hummed.

gizmoe · 9 years ago 0 Thumbs up 0 Thumbs down Comment Add a comment Submit · just now Report Abuse Nothing is open today.